True
Product Image

Rock Flex

0 LE
(0% Off)

Rock Flex

Create a new review

ROCK FLEX is an Elastomeric high performance, prefabricated, modified bitumen membrane consisting of proprietary waterproofing bitumen compound, reinforced with non-woven polyester Carrier.

1 https://rockal.odoo.com/web/image/product.template/56090/image_1920?unique=d7f79ed

0 LE 0 LE 0.0 EGP

0 LE

(0% Off)
Days
:
Hours
:
Mins
:
Secs

    This combination does not exist.

    SKU:
    N/A

    Description

    ROCK FLEX is an Elastomeric high performance, prefabricated, modified bitumen membrane consisting of proprietary waterproofing bitumen compound, reinforced with non-woven polyester Carrier.

    ROCK FLEX proprietary waterproofing com- pound is formulated with high grade bitumen modified with Styrene Butadiene Styrene (SBS) polymer which provides additional elasticity flexibility and dynamic resistance. The membrane withstands temperature fluctuations and high mechanical loads providing a long-term, reliable and effective waterproofing.

    To improve the UV resistance and durability for The Product, the membrane is coated with Mineral Stabilizers.

    Application

    ROCK PROOF waterproofing membrane are used for a wide variety of application:

    • Roofing or Re-roofing for covered single layer  system or as a base layer for multi-layer systems.
    • Wet area, Swimming Pool and Toilets.
    •  Underground waterproofing
    •  Flat and Sloped roofing

     The Product could be applied for waterproofing of foundations and engineering structures by torching hot air generator or by using special adhesives in both cold and hot applications

    • Based on surface conditions, a coat of ROCKAL primer product will be required prior to the application of the membrane.
    •  According to the waterproofing system design and adhesion instruction, SBS-Product can be applied to the substrate fully bonded, semi bonded or loose laid. 
    • Please refer to the ROCKAL application guide for complete instruction on the application of the product

    Key Features:

    • High U.V. resistance (Mineral Finish).
    • Excellent thermal resistance
    • Strong adhesion to substrate
    • Proven water impermeability

    Chemical resistance to wide range of light acidic, alkaline solutions and bacteria.

    Reinforcement

    There are several types of reinforcement materials used in bituminous membranes, including:

    • Non- woven Glass fiber Reinforcement: provides tensile strength and dimensional stability

    • Non-woven polyester fabric: provides tensile strength and stability

    • Non-woven Polyester reinforcement reinforced with fiberglass filaments composite : Very high tensile strength, excellent elongation properties and good dimensional stability.
    • Compound Base: High tensile strength and good dimensional stability 

    The choice of reinforcement material depends on the specific requirements of the roofing system and the desired properties such as reflectivity, dimensional stability, and resistance to environmental factors.

    Surface Finish

    The surface finish of a bituminous membrane refers to the final appearance of the membrane once it has been installed on the roof. The surface finish can have an impact on the overall aesthetic of the roof, as well as its performance. Some common types of surface finishes for bituminous membranes include:

    • Sand finish: a rough, textured surface that helps to increase the coefficient of friction and improve slip resistance, Specially (White/Yellow)

    • Granulated finish: a surface that is covered with small, granulated particles, typically made of a durable material such as aluminum oxide. This finish provides a high level of slip resistance and UV stability. Available in colors (Red, Grey, Green)

    • Smooth finish: a smooth surface that provides a sleek, modern appearance, but may have lower slip resistance compared to other finishes.

    The choice of surface finish depends on the specific requirements of the roofing system, such as the desired level of slip resistance and the type of roof deck.

    Methods of Installation

    SBS (Styrene Butadiene Styrene) bituminous membranes are installed using a variety of methods, including:

    • Heat welded seam method: involves heating the overlapped edges of the membrane with a propane torch to create a seamless, watertight bond between the two pieces of membrane.

    • Cold adhesive method: involves using a cold-applied adhesive to bond the membrane to the roof deck.

    • Mechanically fastened method: involves using special mechanical fasteners to attach the membrane to the roof deck.

    • Ballasted method: involves placing heavy stones or pavers on top of the membrane to keep it in place, without the need for fasteners or adhesives.

    The choice of installation method will depend on factors such as the type of roof deck, the local building codes and regulations, and the desired level of seam strength and durability. It is recommended to seek the guidance of a professional roofing contractor for the installation of an SBS bituminous membrane.

    TestTest MethodToleranceResultUnitاإلختبــــــــار
    ThicknessEN 1849-1±5%4mmالسمك
    WidthEN 1848-1±1%1mالعرض
    LengthEN 1848-1±1%10mالطول
    StraightnessEN 1848-1-± 6mmدرجة اإلستقامة

    Softening Point (R&B) Flexibility at low temperature

    Flow resistance at elevated temperature

    ASTM D-36

    EN 1109 ASTM D-5147 EN 1110 ASTM D-5147

    -

    -10

    110

    - 7 : - 10

    110

    0C

    0C

    0C

    درجة التطرية المرونة عند درجات الحرارة المنخفضة الثبات عند درجات الحرارة العالية
    Tensile Strength-LongitudinalEN 12311-1ASTM D-5147± 20%600N/5cmمقاومة الشد القصوي-طوليا
    Tensile Strength-TransverseEN 12311-1ASTM D-5147± 20%350N/5cmمقاومة الشد القصوي-عرضيا
    Elongation @Break -LongitudinalEN 12311-1ASTM D-5147± 1535%معدل اإلستطالة - طوليا
    Elongation @Break -TransverseEN 12311-1ASTM D-5147± 1540%معدل اإلستطالة - عرضيا
    Tearing Strength-LongitudinalEN 12310-1200Nمقاومة التمزق-طوليا
    Tearing Strength-TransverseEN 12310-1180Nمقاومة التمزق-عرضيا
    Tensile Tear Resistance-LongitudinalASTM D-5147 D-4073± 20%400Nمقاومة  التمزق بطريقة الشد-طوليا
    Tensile Tear Resistance-TransverseASTM D-5147 D-4073± 20%350Nمقاومة التمزق بطريقة الشد-عرضيا
    Resistance to Static LoadingEN 1273010Kgمقاومة اإلختراق اإلستاتيكى
    Resistance to Impact LoadingEN 12691800mmمقاومة اإلختراق الديناميكى
    Shear Resistance of joint L/TEN 12317-1± 20%600/350N/5cmمقاومة الشد عند منطقة التركيب
         )طوليا/عرضيا(
    Dimensional Stability L/TEN 1107-1-1%ثبات األبعاد
    Adhesion to concretePelage UEATC-40N/5cmقوة اإللتصاق باالسطح الخرسانية
    Water absorptionASTM D-51470.15%

     درجة إمتصاص الماء

    Fire Classification - Extremal FireEN 13501-5-F roof-تصنيف الحريق-أداء الحريق
    Performance    الخارجي
    Reaction to fireEN 13501-1-F-رد الفعل عند التعرض للنار
    Water ImpermeabilityEN 1928 method A-Pass10Kpaعدم نفاذية الماء
    Thermal Ageing in airEN 1296-Pass-اإلهتراء نتيجة التسخين
    (in oven 4 weeks at 70 ± 2°C)     
    Ageing Due to Atmospheric Agents (U.V. Test weathering)ASTM G 53 UNI 8202/29-Pass-

    مقاومة التقادم لالشعة

    فوق البنفسجية

    Average loss of slatesEN 1203930%متوسط الفاقد من الحبيبات

    The manufacturer reserves the right to change the specification of the product or its performance, or the contents of the guide, without any prior notice.

    •  Note Products could vary in: Thickness - 3:4mm

    •  ± All Tolerances according to UEAtc Directives

    •  PES: Non-Woven Polyester Reinforcement Carrier

    •  This TDS issued 01/2020 Revoke all previous issued

    This is a preview of the recently viewed products by the user.
    Once the user has seen at least one product this snippet will be visible.

    Recently viewed Products

    To install this Web App in your iPhone/iPad press and then Add to Home Screen.